USB Power Delivery and Type-C 測試分析儀 (GRL-USB-PD-C2)

簡介

  • 完全整合 - 5機一體
  • 支援完整 USB Type-C Power Delivery 3.0 and 2.0 認證測試
  • 兩個獨立TypeC 測試port - Source/Sink 最高達200瓦
  • 支援DisplayPort and Thunderbolt 3 Alt Modes電性自動化測試
  • 整合Qualcomm Quick Charge 4+ and Thunderbolt 3-特殊測試項目

概述

    GRL-USB-PD-C2 (GRL-C2)是唯一同時支援USB Power Delivery 3.0 and USB Type-C Alternate Mode 的認證測試設備, 開發人員只需簡單的按幾個按鍵就可以快速完整的測試驗證你的產品.
    GRL-C2提供自動,高效率且完全自動化整合的方式,藉由USB Type-C介面進行所有USB Power Delivery 3.0和2.0以及相關的測試項目,以及USB Type-C Alt-Mode的PHY自動化測試。 GRL-C2可自動測試power providers (充電器), consumers, dual-role ports, cable 以及 adapter E-Markers所有USB PD相容性測試;並且是唯一可用於Qualcomm Quick Charge 4+和Intel Thunderbolt特定測試項目的解決方案。 GRL-C2還結合了分析器功能錄製PD所有溝通內容。 GRL-C2將所有必需的USB PD測試整合到一個測試設備中。

主要功能

  • Supports all required USB Power Delivery version 3.0 and 2.0 and related tests over the USB Type-C connector in one platform
  • Integrated PHY Test Controller for DisplayPort, Thunderbolt 3, and HDMI Alternate Mode testing
  • Integrated AUX Controller for DisplayPort Source and Sink Physical Layer Testing supporting multiple oscilloscope and BERT platforms
  • USB PD protocol analyzer/sniffer mode, configurable between integrated UFP/DFP controller to DUT or as a ‘pass through’ using extension adapter
  • Supports all USB PD devices including cable and adapter E-Markers, power providers (chargers), power consumers, and dual-role devices
  • Supports DisplayPort Alt Mode CTS Chapter 10 PD Protocol tests
  • Provides two independent PD test ports with 240W Provider and 200W Consumer emulation
  • Integrates Qualcomm Quick Charge 4+ and Intel Thunderbolt-specific tests
  • Supports BMC-PHY-TX with any Windows7+ oscilloscope from Keysight, Tektronix, Rohde & Schwarz, or Teledyne LeCroy
  • Runs all other USB PD tests internally, greatly reducing test times
  • Access to CC1, CC2, Vbus signals for waveform capture via front panel extension adapter
  • All waveforms saved for further analysis and debug
  • Automatically generates comprehensive .pdf, .csv, and .xml test reports

GRL-USB-PD-STC - GRL Special (GRL-SPL) Type-C VCONN Passthrough test cable, used for connecting UUT to GRL-USB-PD-C2 test controller. This is a full feature cable with all Type-C lines connected in between both ends of the cable.

Download Document
GRL-USB-PD-DPC - GRL DPC PHY Tx Automation Test Board, which comprises the following:
  • GRL-C2-EXT1 DisplayPort Fixture, LFPS - EXT1 extension fixture for GRL-USB-PD-C2 test controller, used to:
    • Test DisplayPort Alt Mode over Type-C.
    • Control Low Frequency Periodic Signaling (LFPS) sequences in USB 3.0 system.
  • Support for DP PHY automation using GRL-USB-PD-C2 test controller.
Download Document
GRL-USB-PD-FRS - GRL Fast Role Swap (FRSWAP) Board, which comprises the following:

  • GRL-C2-FRSWAP AUTO Box Board - Fixture for GRL-USB-PD-C2 test controller, used to automate Fast Role Swap based testing. Connects to DUT to remove External AC power from DUT.
  • GRL-C2-EXT5 Extension Board - EXT5 extension fixture for GRL-USB-PD-C2 test controller, used to:
    • Control inputs/outputs from C2.
    • Provide signal triggering for FRSWAP, GRL-USB-PD-SHT extension fixture and other peripherals.
  • FR-SWAP-CAB - FRSWAP test cable, used for connecting GRL-C2-EXT5 extension board with GRL-C2-FR-SWAP-AUTO fixture.
Download Document
GRL-USB-PD-FCB - GRL Type-C Functional Compliance Board, which comprises the following:
  • GRL-HS-EXT Fixture - Extension fixture for GRL-USB-PD-C2 test controller, used to control VBUS and CC lines between connected devices without interfering the high speed lines between Type-C input/output connectors.
  • Support for functional compliance testing using GRL-USB-PD-C2 test controller.
  • GRL-C2-Functional-BRD - To support the functional latest CTS requirements (Only Test 4.5.4 need this fixture)
  • GRL-C2-IO-EXT6 - To Provide signal triggering for GRL-C2-Functional-BRD
  • GRL-F1R-TBT-Cable - Thunderbolt input/output test cable, used for connecting GRL-C2-EXT6 extension board with GRL-C2-Functional-BRD extension fixture.
Download Document
GRL-USB-PD-PWR - GRL Type-C VBUS & VCONN Shorting Board, which comprises the following:
  • GRL-C2-EXT5 Extension Board - EXT5 extension fixture for GRL-USB-PD-C2 test controller, used to:
    • Control inputs/outputs from C2.
    • Provide signal triggering for FRSWAP and other peripherals.
  • GRL-USB-PD-SHT2 - Extension fixture for GRL-USB-PD-C2 test controller, used to connect to Port 1 and Port 2 of GRL-USB-PD-C2 test controller to perform external short circuit for VBUS and VCONN to ground using control signals from GRL-C2-EXT5 extension board.
  • F1R-IO-TBT-Cable - Thunderbolt input/output test cable, used for connecting GRL-C2-EXT5 extension board with GRL-USB-PD-SHT2 extension fixture.
  • Support for Thunderbolt power testing using GRL-USB-PD-C2 test controller (VBUS and VCONN shorting to ground).

Note: This test requires "GRL-USB-PD-PSP" software license, please Contact GRL to purchase.

Download Document
GRL-USB-PD-SNIF - GRL Type-C Sniffer Board, which comprises the following:
  • GRL-C2-EXT2 Sniffer_V2 – Extension fixture for GRL-USB-PD-C2 test controller, used to sniff USB Power Delivery traffic and Qualcomm Quick Charge legacy traffic.
Download Document
GRL-USB-PD-BCSINK - BC Sink Testing Accessory Board. BC Sink testing extension board used for testing the Battery Charge Sinks to check the backward compatibility with BC 1.2. It comprises the following:
  • BC Extension Board - to support the BC 1.2 sink test cases.
  • GRL-C2-EXT5 Extension Board - for GRL-USB-PD-C2 test controller, used to:
    • Control inputs/outputs from C2.
    • Control BC Extension Board.
  • GRL-F1R-TBT-Cable - Thunderbolt input/output test cable, used for connecting GRL-C2-EXT5 extension board with GRL-C2-BC- extension fixture.

Note: Detailed test items can be found in the user guide.

Download Document

GRL-USB-PD-MULT - Used to test multiple DUTs with GRL-USB-PD-C2 controller. At a time 5 DUTs can be connected to 5 Ports of fixture and testing can be execute one after one DUT. It consists of 5 Port Testing Fixture.

Download Document
Note: Granite River Labs recommends connecting the extension fixture/board to the GRL-USB-PD-C2 test controller only when it's powered-off.
USB Power Delivery and Type-C® Tester and Analyzer
Download Link

Your Name (required)

Your Email (required)

Subject

Your Message


Request A Quote

Email (required)

First name (required)

Last name (required)

Title

Company (required)


Download Datasheet

Email (required)

First name (required)

Last name (required)

Title

Company (required)



Download SW/FW

Email (required)

First name (required)

Last name (required)

Title

Company (required)